Chapter 2 87
One-Button Measurement Functions
MEASURE (Spectrum Analysis Mode)
One-Button Measurement Functions
Example: FETC:SEM? or MEAS:SEM? or READ:SEM?
n=11 Returns 12 comma-separated scalar values (in dBc) of the peak
power relative to the carrier at the segment frequencies (14 when
offset F is active):
1. Reserved for the future use, returns –999.0
2. Reserved for the future use, returns –999.0
3. Negative offset frequency (A)
4. Positive offset frequency (A)
11.Negative offset frequency (E)
12.Positive offset frequency (E)
If offset F is active:
13.Negative offset frequency (F)
14.Positive offset frequency (F)
n=12 Returns the band power result when in WLAN standard. If not in
WLAN standard the value returned will be –999.0
n=13 Returns the number of failed trace points
n=14 Returns the frequency and amplitude delta from the limit of each
failed point
Measurement Results Available (Continued)
Command /
Condition n Results Returned