7-2
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter7 Card Provisioning
Provisioning Electrical Cards
7.2 Provisioning Electrical Cards
The ONS 15454 electrical cards (DS1-14, DS1N-14, DS3-12, DS3N - 12, D S3E 1-12, D S3E N-12 ,
DS3XM-6, and EC1-12) are pre-provisioned with settings that you can modify to manage transmission
quality. When you open a card in CTC and select the Provisioning tab, the following subtabs are
commonly displayed:
LineSets line setup parameters, such as line coding and line length. This is also where you put
ports in and out of service.
Line ThresholdSets the line-level PM thresholds.
Elect Path ThresholdSets the path-level PM thresholds for electrical (DS-3/DS-1) traffic.
SONET ThresholdSets the path-level PM thresholds for (STS/VT1.5) traffic.
AlarmingSets alarm profiles for individual ports and suppresses alarms. See Chapter 1 0, Alarm
Monitoring and Management, for information about alarm profiles and alarm suppression.
Table 7 -1 provides an overview of DS-1, DS-3, DS3E, and DS3X M parameters (an X means the item is
available for the card). EC1-12 card parameters are shown in Table 7-6 on p age 7-15.
Table7-1 DS-N Card Provisioning Overview
Subtab Provisioning Item
DS1-14/
DS1N-14
DS3-12/
DS3N-12
DS3E1-12/
DS3EN-12 DS3XM-6
Line Port # XXXX
Port NameXXXX
Line Type X X X
Detected Line Type X
Line Coding X X X
Line LengthXXXX
Status XXXX
Line Threshold Port XXXX
CV XXXX
ES XXXX
SES XXXX
LOSS XXX
Elect Path Port X X X
CV X X
ES X X X
SES X X X
SAS X X X
AIS X X X
UAS X X X