8-37
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter8 Performance Monito ring
Performance Monitoring for Optical Cards
8.6.2 OC-12, OC-48, and OC-192 Card Performance Monitoring Parameters
Figure 8-22 shows the signal types that support far-end PMs. Figure 8-23 shows where overhead byte s
detected on the ASICs produce performance monitoring parameters for the OC-12, OC-48, and OC-192
cards.
Figure8-22 Monitored signal types for the OC-12, OC-48, and OC-192 cards
Table8-34 Far-End Line Layer PMs for the OC-3 Card
Parameter Definition
CV-L Far-End Line Code Violation (CV-L) is a count of BIP errors detected by
the far-end line terminating equipment (LTE) and reported back to the
near-end LTE using the REI-L indication in the line overhead. For SONET
signals at rates below OC-48, up to 8 x N BIP errors per STS-N frame can
be indicated using the REI-L. For OC-48 signals, up to 255 BIP errors per
STS-N frame can be indicated. The current CV-L second register is
incremented for each BIP error indicated by the i n co ming RE I-L .
ES-L Far-End Line Errored Seconds (ES-L) is a count of the seconds when at
least one line-layer BIP error was reported by the far-end L TE or an RDI-L
defect was present.
SES-L Far-End Line Severely Errored Seconds (SES-L) is a count of the seconds
when K (see GR-253-CORE for values) or more lin e-la yer BI P e rro rs
were reported by the far-end LTE or an RDI-L defect was present.
UAS-L Far-End Line Unavailable Seconds (UAS-L) is a count of the seconds
when the line is unavailable at the far end. A line becomes unavailable at
the far end when ten consecutive seconds occur that qualify as SES-LFEs
and it continues to be unavailable until ten consecutive seconds occur that
do not qualify as SES-LFEs.
FC-L Far-End Line Failure Count (FC-L) is a count of the number of fa r-end
line failure events. A failure event begins when RF I-L failure is declared,
and it ends when the RFI-L failure clears. A failure event that begins in
one period and ends in another period is counted only in the period where
it began.
55313
ONS 15454
DS1 OC-N
Fiber
Near End
OC-N Signal
STS Path (STS XX-P) Far End PMs Not Supported
ONS 15454
DS1OC-N
Far End
OC-N Signal