7-16
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter7 Card Provisioning
Provisioning Electrical Cards
Thresholds -
Line CV Coding violations Numeric. Defaults:
1312 (15 minutes)
13120 (1 day)
ES Errored seconds Numeric. Defaults:
87 (15 minutes)
864 (1 day)
SES Severely errored seconds Numeric. Defaults:
1 (15 minutes)
4 (1 day)
FC Failure count Numeric. Defaults:
10 (15 minutes)
0 (1 day)
UAS Unavailable seconds Numeric. Defaults:
3 (15 minutes)
10 (1 day)
PPJC-Pdet Positive Pointer Justification
Count, STS Path Detected. See
the Pointer Justification Count
Parameters section on
page 8-12 for more information.
Numeric. Defaults (near end):
60 (15 minutes)
5760 (1 day)
NPJC-Pdet Negative Pointer Justification
Count, STS Path Detected. See
the Pointer Justification Count
Parameters section on
page 8-12 for more information.
Numeric. Defaults
0 (15 minutes)
0 (1 day)
PPJC-Pgen Positive Pointer Justification
Count, STS Path Generated. See
the Pointer Justification Count
Parameters section on
page 8-12 for more information.
Numeric. Defaults:
0 (15 minutes)
0 (1 day)
NPJC-Pgen Negative Pointer Justification
Count, STS Path Generated. See
the Pointer Justification Count
Parameters section on
page 8-12 for more information.
Numeric. Defaults:
0 (15 minutes)
0 (1 day)
Table7-6 EC1-12 Card Parameters (continued)
Subtab Parameter Description Options