10-6
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter10 Alarm Monitoring and Management
Viewing ONS 15454 Alarms
Figure10-4 Viewing fault conditions retrieved under the Conditions tabs
10.2.3.2 Conditions Column Descriptions
Table10-4 lists the tabs column headings and the information recorded in each column.
Table10-4 Conditions Columns Description
Column Information Recorded
Node Node where the condition occurred (displays in network view only)
Object TL1 access identifier (AID) for the alarmed object
Type Card type in this slot
Slot Slot where the condition occurred (displays in network and node view only)
Port Port where the condition occurred
Sev Severity level: CR (critical), MJ (major), MN (minor), NA (not alarmed), NR (not
reported)
SA When checked, indicates a service-affecting alarm
Cond The condition name
Description Description of the condition