7-4
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter7 Card Provisioning
Provisioning Electrical Cards
Step 3 Depending on the setting you need to modify, click the Line, Line Thrshld, Elect Path, or Sonet
Thrshld subtab.
Note See Chapter1 0, Alarm Monito ring and Ma nagement for information about the Alarm
Behavior tab.
Step 4 Modify the settings shown in Table 7-2 on page 7-4. For drop-down lists, select an item from the list.
For numerics, double-click the field and type the new number.
Table7-2 DS-1 Card Parameters
Subtab Parameter Description Options
Line Port # Port number 1 - 14
Port Port name To enter a name for the port, click the
cell and type the name. To change a
name, double-click the cell, then edit
the text.
Line Type Defines the line framing type D4 (default)
ESF - Extended Super Frame
Unframed
Line
Coding Defines the DS-1 transmission
coding type AMI - Alternate Mark Inversion
(default)
B8ZS - Bipolar 8 Zero Substitution
Line
Length Defines the distance (in feet)
from backplane connection to
the next termination point
0 - 131 (default)
132 - 262
263 - 393
394 - 524
525 - 655
Status Places port in or out of service Out of Service (default)
In Service
Line
Thrshold CV Coding violations Numeric. Defaults:
13340 (15 min)
133400 (1 day)
ES Errored seconds Numeric. Defaults:
65 (15 min)
648 (1 day)
SES Severely errored seconds Numeric. Defaults:
10 (15 minutes)