7-15
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter7 Card Provisioning
Provisioning Electrical Cards
Step 2 Click the Provisioning tab.
Step 3 Depending on the setting you need to modify, click the Line, Thresholds, or STS subtab.
Note See Chapter1 0, Alarm Monito ring and Ma nagement for information about the Alarm
Behavior tab.
Step 4 Modify the settings shown in Tab le 7-6. For drop-down lists, select an item from the list. For numerics,
double-click the field and type the new number.
Table7-6 EC1-12 Card Parameters
Subtab Parameter Description Options
Line Port # EC-1 card port # 1 - 12
Port Name Name assigned to the port
(optional) To enter a name for the port, click
the cell and type the name. To
change a name, double-click the
cell, then edit the text.
PJStsMon# Sets the STS that will be used
for pointer justification. If set to
zero, no STS is used. See the
Pointer Justification Count
Parameters section on
page 8-12 for more information.
0 (default)
1
Line Buildout Defines the dista nce (in feet )
from backplane to next
termination point
0 - 225 (default)
226 - 450
Rx
Equalization For early EC1-12 card versions,
equalization can be turned off if
the line length is short or the
environment is extremely cold;
Rx Equalization should
normally be set to On
On (checked, default)
Off (unchecked)
Status Places the port in or out of
service Out of Service (default)
In Service