CY7C67300

PWM Registers

There are eleven registers dedicated to PWM operation. Each of these registers are covered in this section and summarized in Table 124.

Table 124. PWM Registers

 

 

Register Name

 

 

 

 

Address

 

R/W

PWM Control Register

 

 

 

 

 

 

0xC0E6

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWM Maximum Count Register

 

 

 

 

0xC0E8

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWM0 Start Register

 

 

 

 

 

 

0xC0EA

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWM0 Stop Register

 

 

 

 

 

 

0xC0EC

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWM1 Start Register

 

 

 

 

 

 

0xC0EE

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWM1 Stop Register

 

 

 

 

 

 

0xC0F0

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWM2 Start Register

 

 

 

 

 

 

0xC0F2

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWM2 Stop Register

 

 

 

 

 

 

0xC0F4

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWM3 Start Register

 

 

 

 

 

 

0xC0F6

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWM3 Stop Register

 

 

 

 

 

 

0xC0F8

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWM Cycle Count Register

 

 

 

 

 

 

0xC0FA

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWM Control Register [0xC0E6] [R/W]

 

 

 

 

 

 

 

 

 

 

Table 125. PWM Control Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit #

15

14

 

13

12

 

11

 

10

 

9

8

 

Field

PWM

 

 

Reserved

 

 

 

 

Prescale

 

Mode

 

Enable

 

 

 

 

 

 

 

Select

 

Select

 

Read/Write

R/W

-

 

-

-

 

R/W

 

R/W

 

R/W

R/W

 

Default

0

0

 

0

0

 

0

 

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit #

7

6

 

5

4

 

3

 

2

 

1

0

 

 

PWM 3

PWM 2

 

PWM 1

PWM 0

 

PWM 3

 

PWM 2

 

PWM 1

PWM 0

 

Field

Polarity

Polarity

 

Polarity

Polarity

 

Enable

 

Enable

 

Enable

Enable

 

Select

Select

 

Select

Select

 

 

 

 

 

 

 

 

Read/Write

R/W

R/W

 

R/W

R/W

 

R/W

 

R/W

 

R/W

R/W

 

Default

0

0

 

0

0

 

0

 

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Register Description

The PWM Control register provides high level control over all four of the PWM channels.

PWM Enable (Bit 15)

The PWM Enable bit starts and stops PWM operation.

1:Start operation

0:Stop operation Prescale Select (Bits [11:9])

The Prescale Select field sets the frequency of all the PWM channels as defined in Table 126.

Table 126. Prescaler Select Definition

Prescale Select [11:9]

Frequency

000

48.00 MHz

 

 

001

24.00 MHz

 

 

010

06.00 MHz

 

 

011

01.50 MHz

 

 

100

375 kHz

 

 

101

93.80 kHz

 

 

110

23.40 kHz

 

 

111

05.90 kHz

 

 

Document #: 38-08015 Rev. *J