CY7C67300

AC Timing Characteristics

Reset Timing

tRESET

nRESET

nRD or nWRL or nWRH

tIOACT

Reset Timing

Table 135. Reset Timing Parameters

Parameter

Description

Min

Typical

Max

Unit

tRESET

nRESET Pulse Width

16

 

 

clocks[11]

tIOACT

nRESET HIGH to nRD or nWRx active

200

 

 

µs

Clock Timing

tCLK

XTALIN

tHIGH

tLOW

tFALL

tRISE

Clock Timing

Table 136. Clock Timing Parameters

Parameter

Description

Min

Typical

Max

Unit

fCLK

Clock Frequency

 

12.0

 

MHz

vXINH[12]

Clock Input High

1.5

3.0

3.6

V

 

(XTALOUT left floating)

 

 

 

 

tCLK

Clock Period

83.17

83.33

83.5

ns

tHIGH

Clock High Time

36

 

44

ns

tLOW

Clock Low Time

36

 

44

ns

tRISE

Clock Rise Time

 

 

5.0

ns

tFALL

Clock Fall Time

 

 

5.0

ns

Duty Cycle

 

45

 

55

%

 

 

 

 

 

 

Notes

11.Clock is 12 MHz nominal.

12.vXINH is required to be 3.0 V to obtain an internal 50/50 duty cycle clock.

Document #: 38-08015 Rev. *J

Page 85 of 99