Reference, Installation, and Operations Manual

Section 3: Installation

3-9000-743 Rev S

June 2013

 

 

 

3.5.2Frequency and Digital Output switch settings

The meter provides two pairs of configurable frequency outputs (FO1A, FO1B, FO2A, and FO2B) and four configurable digital outputs (DO1A, DO1B, DO2A, and DO2B). These outputs are divided into two groups as follows:

Group 1: FO1A, FO1B, DO1A, DO1B

Group 2: FO2A, FO2B, DO2A, DO2B

The frequency and digital outputs are individually configured for “internally powered” mode or “open collector” mode via CPU Board switch banks S8 and S9 (see Figure 3-25 and Figure 3-26). See Section 2.4.4 for information on these modes.

Figure 3-25 CPU Board Frequency and Digital Output configuration switch banks

S 8

Group 1S8Outputs

S 9

S9 Group 2Outputs

Frequency and Digital Output switch settings

79