Section 6: Meter operation

Reference, Installation, and Operations Manual

June 2013

3-9000-743 Rev S

 

 

Table 6-19 Hourly log content

Data Point

 

Log Action

 

 

 

PrevDayMacro2*:

 

Macro

 

 

 

bit 31

(unused)

 

bit 30

IsMeasSndSpdRange

 

bit 29

IsAvgSoundVelRangeErr

 

bit 28

IsMeterVelAboveMaxLmt

 

bit 27

IsHardFailedA

 

bit 26

IsHardFailedB

 

bit 25

IsHardFailedC

 

bit 24

IsHardFailedD

 

bit 23

(unused)

 

bit 22

IsSNRTooLow

 

bits 21-19

(unused)

 

bit 18

PressureInvalid

 

bit 17

TemperatureInvalid

 

bit 16

IsAnyLogFull

 

bit 15

(unused)

 

bit 14

IsGCWarningPresent

 

bit 13

PressHARTIsPVOutOfLimits

 

bit 12

TempHARTIsPVOutOfLimits

 

bit 11

PressHARTIsMoreStatusAvailable

 

bit 10

TempHARTIsMoreStatusAvailable

 

bit 9

IsBlockageDetected

 

bit 8

IsBoreBuildupDetected

 

bit 7

IsLiquidDetected

 

bit 6

IsAbnormalProfileDetected

 

bit 5

IsReverseFlowDetected

 

bit 4

IsSoundVelCompErr

 

bit 3-0

(unused)

 

 

 

 

SndVelA,

 

Flow-Gated

SndVelB,

 

 

SndVelC,

 

 

SndVelD

 

 

 

 

 

FlowVelA,

 

Flow-Gated

FlowVelB,

 

 

FlowVelC,

 

 

FlowVelD

 

 

 

 

 

AvgFlow

 

Flow-Gated

 

 

(Percent of good batch signals)

Average

PctGoodA1, PctGoodA2

 

PctGoodB1, PctGoodB2,

 

PctGoodC1, PctGoodC2,

 

PctGoodD1, PctGoodD2

 

 

 

 

QFlow

 

Flow-Gated

 

 

 

QBase

 

Flow-Gated

 

 

 

238

Hourly log