Section 5: Startup and meter configuration

Reference, Installation, and Operations Manual

June 2013

3-9000-743 Rev S

 

 

Table 5-11 Daniel MeterLink Field Setup Wizard

Page

Description

 

 

Temperature and Pressure

The Temperature and Pressure Page allows you to set the scaling for analog inputs, enter fixed

Page

values, and set alarm limits for both temperature and pressure. This page is only displayed if either

See Section 5.6.12

temperature or pressure was set to Live or Fixed on the Startup Page.

 

 

 

 

Temperature

 

 

Live temperature Enabled if Live was selected for Temperature for meter corrections

 

 

 

on the Startup Page. Enter in the scaling for the transmitter connected to the analog

 

 

 

input. Min. input is the zero scale temperature of the transmitter (i.e. 1 Volt or 4 mA).

 

 

 

Max. input is the full scale temperature of the transmitter (i.e. 5 Volts or 20 mA).

 

 

Fixed temperature: Enabled if Fixed was selected for Temperature for meter correc-

 

 

 

tions on the Startup Page. Enter an average temperature of the process fluid.

 

 

 

 

Temperature alarm

 

 

Enter the low and high alarm limits. A temperature reading outside of these limits causes a

 

 

Temperature Validity alarm.

 

 

 

 

Pressure

 

 

Is pressure gage or absolute

 

 

 

Select either Gage or Absolute for the type of pressure reading desired. If a live

 

 

 

pressure transmitter is connected, select the type of reading the transmitter

 

 

 

outputs. If Absolute is selected, you must also enter the Atmospheric pressure.

 

Live pressure

 

 

Enabled if Live was selected for Pressure for meter corrections on the Startup Page.

 

 

 

Enter in the scaling for the transmitter connected to the analog input. Min. input is

 

 

 

the zero scale pressure of the transmitter (i.e. 1 Volt or 4 mA). Max. input is the full

 

 

 

scale pressure of the transmitter (i.e. 5 Volts or 20 mA).

 

Fixed pressure

 

 

Enabled if Fixed was selected for Pressure for meter corrections on the Startup Page.

 

 

 

Enter an average pressure of the process fluid.

 

Pressure alarm

 

 

Enter the low and high alarm limits. A pressure reading outside of these limits causes

 

 

 

a Pressure Validity alarm.

 

 

 

 

130

Meter configuration using Daniel MeterLink