Reference, Installation, and Operations Manual

Section 5: Startup and meter configuration

3-9000-743 Rev S

June 2013

 

 

 

Dry calibration

The meter uses a third-order polynomial for dry calibration as shown in Equation 6-8. Click the Advanced View button to display the zero flow calibration polynomial coefficients. Regardless of what flow calibration method is selected, the zero flow calibration polynomial coefficients will be applied first.

Modification of dry calibration parameters is not recommended. The dry calibration parameters should not be modified unless directed by Daniel personnel.

The meter provides separate dry calibration coefficients for each flow direction as listed in the table below.

Table 5-22 Data Points for Dry Calibration

Daniel MeterLink

Data Points, Options and Guidelines

Display Name

 

 

 

 

Forward A0

Data points affected:

 

FwdA0

 

Options:

 

Enter a value (m/s or ft/s) within the range [-1,1 m/s].

 

Guidelines:

 

This value should only be modified under direction of Daniel personnel.

 

For additional guidelines, see Section 6.1.8 and Daniel MeterLink online help.

 

 

Forward A1

Data points affected:

 

FwdA1

 

Options:

 

Enter a value (dimensionless) within the range [0.95,1.05].

 

Guidelines:

 

This value should only be modified under direction of Daniel personnel.

 

For additional guidelines, see Section 6.1.8 and Daniel MeterLink online help.

 

 

Forward A2

Data points affected:

 

FwdA2

 

Options:

 

Enter a value (s/m or s/ft) within the range [-0.1,0.1 s/m].

 

Guidelines:

 

This value should only be modified under direction of Daniel personnel.

 

For additional guidelines, see Section 6.1.8 and Daniel MeterLink online help.

 

 

 

Set calibration parameters