Section 5: Startup and meter configuration

Reference, Installation, and Operations Manual

June 2013

3-9000-743 Rev S

 

 

Table 5-15 Data Points for Analog (Current) Output Configuration

Daniel MeterLink

Data Points, Options and Guidelines

Display Name

 

 

 

 

Maximum scale velocity:

Data points affected:

Series 100 Option Board

AO1MaxVel

Series 100 Plus Option Board

AO2MaxVel

(if installed)

Options:

 

Enter a velocity value (m/sec or ft/sec)

 

Guidelines

 

This point is only used when the analog output content is either

 

 

the average flow or sound velocity.

 

This point specifies the (flow or sound) velocity associated with

 

 

the maximum current (20 mA).

 

For options and guidelines, see Section 6.2.3 and Daniel

 

 

MeterLink online help.

 

 

Minimum scale velocity:

Data points affected:

Series 100 Option Board

AO1MinVel

Series 100 Plus Option Board

AO2MinVel

(if installed)

Options:

 

Enter a velocity value (m/sec or ft/sec)

 

Guidelines

 

This point is only used when the analog output content is either

 

 

the average flow or sound velocity.

 

This point specifies the (flow or sound) velocity associated with

 

 

the minimum current (4 mA).

 

For options and guidelines, see Section 6.2.3 and Daniel

 

 

MeterLink online help.

 

 

Full scale energy rate:

Data points affected:

Series 100 Option Board

AO1FullScaleEnergyRate

Series 100 Plus Option Board

AO2FullScaleEnergyRate

(if installed)

Options:

 

Enter an energy rate (MJ/hr or MMBTU/hr)

 

Guidelines

 

This point is only used when the analog output content is energy

 

 

rate.

 

This point specifies the energy rate associated with the maximum

 

 

current (20 mA).

 

For options and guidelines, see Section 6.2.3 and Daniel

 

 

MeterLink online help.

 

 

 

142

Current Outputs Page