Meter setup and configuration worksheet

Reference, Installation, and Operations Manual

June 2013

3-9000-743 Rev S

Table E-2 Meter to Flow Computer Communication Worksheet (Sheet 8 of 9)

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Analog Output

User Selection (Circle one)

 

 

 

 

 

Results (Enter here)

AO1

 

 

 

 

 

 

 

 

(Option Board or

 

 

 

 

 

 

 

 

Series 100 Option Board)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Configuration

Sink

Source (i.e., powered by the meter) If the analog output is configured for

 

 

 

 

 

source mode, then it must be at the bottom of the loop (stack).

 

 

 

 

 

 

 

 

 

 

Direction

Forward

Reverse

Absolute

 

 

 

 

 

 

 

 

 

Full Scale Flow Rate

Refer to note in Modbus volume and flow rate units section of this table.

 

 

 

 

 

 

 

 

 

 

 

Analog Output

User Selection (Circle one)

 

 

 

 

 

Results (Enter here)

AO2

 

 

 

 

 

 

 

 

(Series 100 Option Board)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Configuration

Sink

Source (i.e., powered by the meter) If the analog output is configured for

 

 

 

 

 

source mode, then it must be at the bottom of the loop (stack).

 

 

 

 

 

 

 

 

 

 

Direction

Forward

Reverse

Absolute

 

 

 

 

 

 

 

 

 

Analog Input

Live or specified temperature can be used for bulk volume correction.

 

 

 

 

AI1 (Temperature)

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Configuration

Sink

Source (i.e., powered by the meter)

 

 

 

If the analog input is configured for source mode, then it must be at the

 

 

 

bottom of the loop (stack).

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Input

______oC

______oF

 

 

 

 

(temperature

 

(if metric units system selected)

 

(if US Customary units

 

 

 

 

corresponding to 4mA input)

 

 

 

system selected)

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Input

______oC

______oF

 

 

 

 

(temperature

 

 

 

 

 

 

 

 

corresponding to 20mA input)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Alarm

______oC

______oF

 

 

 

 

High Alarm

______oC

______oF

 

 

 

 

Note: If the temperature is at or outside these limits, an alarm is generated

Note: Temperature is required for optional meter internal diameter Temperature expansion correction. If a temperature transmitter is connected to the meter, select Live for this option. If a temperature transmitter is not connected to the meter but temperature expansion correction is required, select Fixed. You will enter in a fixed temperature on a later page. If the correction is not required, select Not used.

329

Meter to Flow Computer Communication Worksheet