Reference, Installation, and Operations Manual

Section 5: Startup and meter configuration

3-9000-743 Rev S

June 2013

 

 

 

 

For controlling how batches are run, configure these data points which are displayed in the

 

Daniel MeterLink Update Time Wizard (listed in the table below):
Table 5-21 Data Points for Batch Cycle Processing, or Update Time Control

 

 

 

Daniel MeterLink

Data Points, Options and Guidelines

Display Name

 

 

 

 

 

 

 

Update Rate

 

Data points affected:

 

 

SpecBatchUpdtPeriod

 

 

Options:

 

 

Standard (1000 ms)

 

 

Rapid (250 ms)

 

 

Guidelines:

 

 

For additional guidelines, see Section 6.1.3 and Daniel MeterLink online

 

 

 

help.

 

 

 

Stack Size

 

Data points affected:

 

 

StackSize

 

 

Options:

 

 

None (1)

 

 

2 (2)

 

 

4 (4)

 

 

8 (8)

 

 

16 (16)

 

 

Guidelines:

 

 

Stacking (i.e., stack size other than None) is only available with the Standard

 

 

 

update rate.

 

 

For additional guidelines, see Section 6.1.3 and Daniel MeterLink online

 

 

 

help.

 

 

 

Filter

 

Data points affected:

 

 

Filter

 

 

Options:

 

 

Off (FALSE)

 

 

On (TRUE)

 

 

Guidelines:

 

 

Filtering is only available with the Standard update rate. It is not available with

 

 

 

the Rapid update rate.

 

 

For additional guidelines, see Section 6.1.3 and Daniel MeterLink online

 

 

 

help.

 

 

 

 

Update Time Wizard

161