Reference, Installation, and Operations Manual

Meter setup and configuration worksheet

3-9000-743 Rev S

June 2013

Table E-2 Meter to Flow Computer Communication Worksheet (Sheet 5 of 9)

Description

 

 

 

 

 

 

 

 

 

 

 

 

Digital Output Group 1 DO1B

User Selection (Circle one)

 

 

 

Results (Enter here)

 

 

 

 

 

 

 

Electrical Configuration

TTL

OC

 

 

 

“Internally Powered”

 

“Open Collector”

 

 

Content

Flow Direction

Flow Validity

 

 

 

 

 

 

 

 

 

Polarity

Normal

Inverted

 

 

 

 

 

 

(see note above)

 

 

 

 

 

 

 

 

 

Note: Digital outputs 1A and 1B share a common ground with Frequency outputs 1A and 1B. Digital outputs 2A and 2B share a common ground with Frequency outputs 2A and 2B. When connecting the ultrasonic meter to two different devices, it is recommended to connect Frequency outputs 1A and 1B and Digital outputs 1A and 1B to one device and Frequency outputs 2A and 2B and Digital outputs 2A and 2B to the other device. This will prevent ground loops.

Frequency Output

User Selection (Circle one)

 

 

 

Results (Enter here)

 

 

 

 

 

 

Electrical Configuration

TTL

OC

 

 

 

 

“Internally Powered”

“Open Collector”

 

 

 

 

 

 

 

 

 

Meter to Flow Computer Communication Worksheet

326