Section 5: Startup and meter configuration

Reference, Installation, and Operations Manual

June 2013

3-9000-743 Rev S

 

 

5.6.13Gas Chromatograph Setup page

Figure 5-16 Field Setup Wizard - Gas Chromatograph Setup page

The Live gas composition from GC check box is only available if the optional GC interface feature is enabled on the Field Setup Wizard - Startup Page, a Series 100 Option Board (or Series 100 Plus Option Board) is installed and a you have a valid GCKey (see Section 430).

1.From the Field Setup Wizard - Gas Chromatograph Page, choose the desired settings:

a.Serial Port: Select which serial port will be connected to the GC. While the port is configured for communications to a GC, it will not act as a Modbus slave device for communications from Daniel MeterLink or a SCADA system.

b.GC protocol: Select the protocol for which the GC is configured. The Mark III uses 7 data bits, Even parity, and 1 stop bit for ASCII Modbus and 8 data bits, No parity, and 1 stop bit for RTU Modbus.

c.GC baud rate: Select the baud rate for which the GC is configured.d.GC comms address: Enter the Modbus ID of the GC.

e.GC stream number: Enter the stream number for the gas composition the Daniel Mark III Gas Ultrasonic meter will read.

f.GC heating value units: Select the units for which the heating value is configured in the GC.

g.GC heating value type: Select the type of heating value the GC will return.

154

Gas Chromatograph Setup page