Reference, Installation, and Operations Manual

Section 2: Product overview

3-9000-743 Rev S

June 2013

 

 

 

2.3.4Flow range limits

The reference condition flow range limits for SeniorSonicTM Meters (pipe sizes from 100 mm to 900 mm) are listed in the appendix tables (see Appendix F).

Daniel should be consulted before establishing the actual meter capacity for a particular application.

The meter capacity at reference (base) conditions of pressure and temperature may be calculated as shown in Equation 2-1.

Equation 2-1 Meter capacity - reference conditions of pressure and temperature

4

= 4

31 7701 =701

701

1

3701 71 =1

where

Qref

Qf

Pf

Pref

Tref

Tf

Zref

Zf

=flow rate at reference conditions (Nm3/h; Scfh)=flow rate at flowing conditions (m3/h; cfh)=absolute pressure at flowing conditions (Pa; psia)=absolute pressure at reference conditions (Pa; psia)=absolute temperature at reference conditions (K; R)=absolute temperature at flowing conditions (K; R)=compressibility of gas at reference conditions (dimensionless)=compressibility of gas at flowing conditions (dimensionless)

Flow range limits