Section 3: Installation

Reference, Installation, and Operations Manual

June 2013

3-9000-743 Rev S

 

 

Table 3-3 Hoist ring lookup table for Daniel Gas JuniorSonic Meters

ANSI 300

ANSI 600

ANSI 900

ANSI 1500

Daniel Part Number

 

 

 

 

 

4” to 12”

4” to 8”

4” to 8”

4” to 6”

1-504-90-091

 

 

 

 

 

16” to 18”

10” to 16”

10” to 12”

8” to 10”

1-504-90-092

 

 

 

 

 

20” to 30”

18” to 20”

16” to 20”

12”

1-504-90-093

 

 

 

 

 

36”

24” to 30”

24”

16” to 20”

1-504-90-094

 

 

 

 

 

 

36”

30” to 36”

24” to 36”

1-504-90-095

 

 

 

 

 

3.2.4Using appropriately rated lifting slings on Daniel Ultrasonic Meters

The following instructions are intended to provide general guidelines for proper slinging of a Daniel Ultrasonic meter by itself. They are intended to be followed in addition to your company's standards or the DOE-STD-1090-2004 HOISTING AND RIGGING standard if such company standards do not exist.

Safety precautions using appropriate rated lifting slings on DanielUltrasonic Meters

Read and follow the Safety Precautions listed below:

1.Meters must only be lifted by personnel properly trained in the safe practices of rigging and lifting.

2.NEVER attempt to lift the meter by wrapping slings around the electronics.

48

Using appropriately rated lifting slings on Daniel Ultrasonic Meters