Serial Port Setup Dialog Box

The Serial Port setup dialog box provides tools to configure serial port Remote 1 (see figure 54).

1

1

7

2

63

4

5

Figure 54. Serial Port Setup Dialog Box Submenu

NOTES: Serial port Remote 1 can be set to disabled, controlmsvpp (control the

player), or passthrough (pass the signals through the player to a controlled

device).

When you are using the passthrough mode, ensure that the Baud Rate,

Data Bits, Stop Bits, and Parity are set to match the device that you

are controlling. Also, in your remote control program, set the IP port number

to 4001 and the IP address to that of media player. When the port is in

passthrough mode, any TCP/IP control string that appears on port 4001 of

the JMP 9600 is passed to the Remote 1 port.

Serial port Remote 2 is for factory use only. The customer or end user cannot control the player via the Remote 2 port.

Configure serial port Remote 1 as follows:

NOTE: You do not need to perform those steps that make changes that are unnecessary for your configuration.

1.Click the Mode drop-down box and select among the settings (see A in figure 54).

2.Click the Baud Rate drop-down box and select among the settings (B).

3.Click the Data Bits drop-down box and select among the settings (C).

4.Click the Stop Bits drop-down box and select among the settings (D).

5.Click the Parity drop-down box and select among the settings (E).

6.Click the Save button or the Cancel button to save or abandon the changes (F).

7.Click the or the Cancel button to close the dialog box (G).

JMP 9600 Media Player • HTML Operation

51

Page 57
Image 57
Extron electronic JMP 9600 manual Serial Port Setup Dialog Box Submenu