Remote Operation

DISPlay Subsystem Commands

Sensitivity

 

 

Set according to automeasure setup panel. In some cases, this

 

 

 

may also be a function of signal characteristics.

dB/div

 

 

Set according to automeasure setup panel. In some cases, this

 

 

 

may also be a function of signal characteristics.

Video Bandwidth

 

 

Auto

Auto Range Enable

 

 

On

Trans-Z Lock

 

 

Off

Repetitive Sweep

 

 

On (front panel), Off (remote control)

Sweep Time

 

 

Auto

Auto Chop Mode

 

 

On

Gated Sweep Enable

 

 

Off

Sweep Trigger Mode

 

 

Internal

Trace Length

 

 

1001

Wavelength Limit

 

 

On

Reference Level

 

 

According to signal amplitude

Linear Display Mode

 

 

Off

Resolution Bandwidth

 

 

According to signal characteristics

Res-BW to Span Ratio

 

 

0.01

Peak Search on EOS

 

 

Off

Line Markers

 

 

Off

Trace Integration Limit

 

 

Off

Search Limit

 

 

Off

Trace Integration

 

 

Off

Trace Mean Calculation

 

 

Off

For each trace, except trace A:

 

 

Trace Math

 

Off

Update

 

Off

View

 

Off

Hold Mode

 

None

Averaging

 

Off

Trace A is identical, except:

 

 

 

Update

 

On

View

 

On

 

 

 

 

4-72