Remote Operation

DISPlay Subsystem Commands

DISPlay[:WINDow[1]]:TRACe:X[:SCALe]:AUTO:SPAN <numeric_value>[MNMUM]

DISPlay[:WINDow[1]]:TRACe:X[:SCALe]:AUTO:SPAN?

Specifies the final span after a DISPlay:WINDow:TRACe:ALL:SCALe:AUTO command.

DISPlay[:WINDow[1]]:TRACe:X[:SCALe]:AUTO:SPAN:AUTO ONOFF10

DISPlay[:WINDow[1]]:TRACe:X[:SCALe]:AUTO:SPAN:AUTO?

Specifies whether the final span after a DISPlay:WINDow:TRACe:ALL: SCALe: AUTO command should be set automatically, based on properties of the measured signal.

DISPlay[:WINDow[1]]:TRACe:Y[:SCALe]:AUTO:PDIVision <numeric_value>[DB]

DISPlay[:WINDow[1]]:TRACe:Y[:SCALe]:AUTO:PDIVision?

Specifies the final vertical scale after performing a DISPlay:WIN-

Dow:TRACe:ALL:SCALe:AUTO command.

DISPlay[:WINDow[1]]:TRACe:Y[12][:SCALe]:AUTO:PDIVision:AUTO OFFON01

DISPlay[:WINDow[1]]:TRACe:Y[12][:SCALe]:AUTO:PDIVision:AUTO?

Specifies whether the final vertical scale after a DISPlay:WIN- Dow:TRACe:ALL:SCALe:AUTO command should be adjusted automatically, based on signal properties. Y1 refers to the left (power) scale, and Y2 refers to the right (ratio) scale.

DISPlay[:WINDow[1]]:TRACe:Y[12][:SCALe]:LINear OFFON01

DISPlay[:WINDow[1]]:TRACe:Y[12][:SCALe]:LINear?

Specifies whether the vertical scale is in linear units or in log units. Y1 refers to the left (power) scale, and Y2 refers to the right (ratio) scale.

4-74