9SCAN OPERATION

Scan types

PROGRAMMED SCAN

Repeatedly scans between two scan edge frequencies (scan edge memory channels 1A and 1B).

 

Scan

Scan edge 1A or 1B

Scan edge 1B or 1A

 

Jump

This scan operates in VFO mode.

PRIORITY WATCH

Checks for signals on a memory while operating on a VFO frequency.

VFO Memory

frequency channel

This scan operates in VFO mode.

MEMORY SCAN

Repeatedly scans all programmed memory channels.

 

ß (select)

BLANK

 

 

Mch 2

Mch 3

Mch 4

Mch 1 ß (select)

 

ß (select) Mch 5

Mch 99

Mch 7

Mch 6

ß (select)

ß (select)

 

This scan operates in memory mode.

SELECTED MEMORY SCAN

Repeatedly scans all selected memory channels.

 

ß (select)

BLANK

 

 

Mch 2

Mch 3

Mch 4

Mch 1 ß (select)

 

ß (select) Mch 5

Mch 99

Mch 7

Mch 6

ß (select)

ß (select)

 

This scan operates in memory mode.

Preparation

• Channels

For programmed scan: Program scan edge frequen- cies into scan edge memory channels 1A and 1B. (p. 103)

For memory scan: Program 2 or more memory chan- nels except scan edge memory channels.

For memory select scan: Designate 2 or more mem- ory channels as select memory channels—select a memory channel, then push [F-2SEL] in the S-2menu (memory mode) to designate the channel as a select memory channel.

For priority watch: Program 1 memory channel to be watched.

•Scan resume ON/OFF

You can select the scan to resume or cancel when de- tecting a signal, in the miscellaneous (others) set mode, item “SCAN Resume.” Scan resume ON/OFF must be set before operating a scan. See p. 135 for ON/OFF setting and scan resume condition details.

Scan speed

Scan speed can be selected from 2 levels, high or low, in the miscellaneous (others) set mode. See p. 135 for details.

•Squelch condition

SCAN

PROGRAMMED

MEMORY SCANS

STARTS

 

SCAN

PRIORITY WATCH

WITH

 

 

 

 

 

The

scan continues

Scan pauses on each

 

until it is stopped man-

channel when the

 

ually,

and does not

scan resume is ON;

 

pause even if it de-

not applicable when

SQUELCH

tects signals.

OFF.

OPEN

This is not applicable

 

when the scan re-

 

 

 

 

sume is OFF and a

 

 

programmable step

 

 

(more than 1 kHz) is

 

 

selected.

 

 

Scan stops when detecting a signal.

SQUELCH

If you set scan resume ON in the miscella-

neous (others)l set mode, the scan pauses for

CLOSED

10 sec. when detecting a signal, then re-

 

sumes. When a signal disappears while scan

 

is paused, scan resumes 2 sec. later.

 

 

 

 

113