•Command table (continued)

Command

Sub command

 

Description

 

 

 

1A

050114

Send/read NR level set

 

 

(0=0 to 15=15)

 

 

050115

Send/read VOX gain (0=0% to

 

 

255=100%)

 

 

050116

Send/read anti VOX gain (0=0% to

 

 

255=100%)

 

 

050117

Send/read VOX delay (0=0.0 sec.

 

 

to 20=2.0 sec.)

 

 

050118

Send/read DTMF speed set

 

 

(0=100

msec.,

1=200 msec.,

 

 

2=300 msec., 3=500 msec.)

 

050119

Send/read Break-IN delay set

 

 

(20=2.0d to 130=13.0d)

 

 

 

06

 

Send/read SSB transmit band-

 

 

width (0=WIDE, 1=MID, 2=NAR)

 

 

 

07

 

Send/read DSP filter shape

 

 

(0= sharp, 1= soft)

 

 

 

08

 

Send/read manual notch filter1

 

 

bandwidth

 

 

 

(0=WIDE, 1=MID, 2=NAR)

 

 

 

09

 

Send/read manual notch filter2

 

 

bandwidth

 

 

 

(0=WIDE, 1=MID, 2=NAR)

 

 

 

0A

 

Send/read 9600 bps mode set

 

 

(0=OFF, 1=ON)

 

1B

00

Set/read repeater tone frequency

 

 

(see p. 149 for details)

 

01

Set/read

TSQL

tone frequency

 

 

(see p. 149 for details)

 

02

Set/read DTCS code and polarity

 

 

(see p. 149 for details)

 

 

 

1C

00

Set/read the transceiver’s condi-

 

 

tion (0=Rx; 1=Tx)

 

 

01

Set/read antenna tuner condition

 

 

(0=OFF, 1=ON, 2=Start tuning or

 

 

while tuning)

 

 

 

 

 

 

CW: Clockwise, CCW: Counter Clockwise

CONTROL COMMAND 17

DTo send/read memory contents

When sending or reading memory contents, additional code as follows must be added to appoint the memory channel.

Additional code: 0000–0102(0100=P1, 0101=P2, 0102=Call)

DBand stacking register

To send or read the desired band stacking register’s con- tents, combined code of the frequency band and register codes as follows are used.

For example, when sending/reading the oldest contents in the 21 MHz band, the code “0703” is used.

•Frequency band code

 

 

 

 

 

Code

Frequency band

Frequency range (unit: MHz)

 

 

 

 

01

1.8

1.800000–

1.999999

 

 

 

 

02

3.5

3.400000–

4.099999

03

7

6.900000– 7.499999

04

10

9.900000–10.499999

05

14

13.900000–14.499999

06

18

17.900000–18.499999

07

21

20.900000–21.499999

08

24

24.400000–25.099999

09

28

28.000000–29.999999

10

50

50.000000–54.000000

11

144

144.000000–148.000000

 

 

 

12

430

430.000000–450.000000

 

 

 

13

GENE

Other than above

 

 

 

 

•Register code

 

 

 

 

 

Code

Registered number

 

 

 

 

 

01

 

1 (latest)

 

 

 

 

 

02

 

2

 

 

 

 

 

03

 

3 (oldest)

 

 

 

 

 

D Codes for memory keyer contents

17

To send or read the desired memory keyer contents, the

channel and character codes as follows are used.

 

• Channel code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

 

 

Channel number

 

 

01

 

 

 

M1

 

 

02

 

 

 

M2

 

 

03

 

 

 

M3

 

 

 

 

 

 

 

 

 

 

 

04

 

 

 

M4

 

 

 

 

 

 

 

 

 

 

 

• Character’s code

 

 

 

 

 

 

 

 

 

 

 

 

 

Character

ASCII code

 

Description

 

 

0–9

30–39

 

Numerals

 

 

A–Z

41–5A

 

Alphabetical characters

 

 

space

20

 

Word space

 

 

/

 

2F

 

Symbol

 

 

?

 

3F

 

Symbol

 

 

,

 

2C

 

Symbol

 

 

.

 

2E

 

Symbol

 

 

^

 

5E

 

e.g., to send

 

, enter ^4254

 

 

 

 

BT

 

 

 

 

 

 

 

 

 

 

2A

 

Inserts contact number (can be

 

 

 

 

 

 

used for 1 channel only)

 

 

 

 

 

 

 

 

 

 

 

148

Page 157
Image 157
Icom IC-7000 instruction manual To send/read memory contents, Band stacking register, Codes for memory keyer contents