BASIC OPERATION

3

Selecting an operating band

HM-151

SPCH

 

TUNER

 

XFC

/LOCK

/CALL

 

 

 

 

 

 

V/M

 

MW

 

 

 

 

 

 

 

 

F-1

 

F-2

 

 

 

 

 

1.8 1

3.5 2

7

3

MODE

10 4

14 5

18 6

FIL

21 7

24 8

28 9

GENE

50 .

144

430

F-INP

 

 

0

 

CE

ENT

The triple band stacking register provides 3 memories in one band. 3 sets of frequency and operating mode on each band are automatically stored when used.

3

If a band key (on the HM-151) is pushed once, the last used frequency and operating mode are called up. When the key is pushed again, another stored fre- quency and operating mode are called up.

This function is convenient when you operate 3 oper-

Band keys ating modes on one band. For example, one register is used for a CW frequency, another for an SSB fre- quency and the other one for an RTTY frequency.

See the table below for a list of the bands available and the default settings for each band.

BAND

REGISTER 1

REGISTER 2

REGISTER 3

1.8 MHz

1.900000 MHz CW

1.910000 MHz CW

1.915000 MHz CW

 

 

 

 

3.5 MHz

3.550000 MHz LSB

3.560000 MHz LSB

3.580000 MHz LSB

7 MHz

7.050000 MHz LSB

7.060000 MHz LSB

7.020000 MHz CW

 

 

 

 

10 MHz

10.120000 MHz CW

10.130000 MHz CW

10.140000 MHz CW

14 MHz

14.100000 MHz USB

14.200000 MHz USB

14.050000 MHz CW

 

 

 

 

18 MHz

18.100000 MHz USB

18.130000 MHz USB

18.150000 MHz USB

21 MHz

21.200000 MHz USB

21.300000 MHz USB

21.050000 MHz CW

 

 

 

 

24 MHz

24.950000 MHz USB

24.980000 MHz USB

24.900000 MHz CW

28 MHz

28.500000 MHz USB

29.500000 MHz USB

28.100000 MHz CW

 

 

 

 

50 MHz

50.100000 MHz USB

50.200000 MHz USB

51.000000 MHz FM

144 MHz

145.000000 MHz FM

145.100000 MHz FM

145.200000 MHz FM

 

 

 

 

430 MHz

433.000000 MHz FM

433.100000 MHz FM

433.200000 MHz FM

General

15.000000 MHz USB

15.100000 MHz USB

15.200000 MHz USB

 

 

 

 

DUsing the band stacking registers

[Example]: 14 MHz band

q Push [(14)5], then select a frequency and an oper- ating mode.

SPCH

 

TUNER

 

XFC

/LOCK

/CALL

 

 

 

 

 

 

V/M

 

MW

 

 

 

F-1

 

F-2

 

 

 

 

 

1.8 1

3.5 2

7

3

MODE

10 4

14 5

18 6

FIL

21 7

24 8

28 9

GENE

50 .

144

430

F-INP

 

 

0

 

CE

ENT

1.8 1

3.5 2

7

3

MODE

10 4

14 5

18 6

FIL

21 7

24 8

28 9

GENE

50 .

144

430

F-INP

 

0

 

CE

ENT

•Frequency and operating mode are memorized in the first band stacking register.

w Push [(14)5] again, then select another frequency and operating mode.

•This frequency and operating mode are memorized in the second band stacking register.

e Push [(14)5] again, then select another frequency and operating mode.

•This frequency and operating mode are memorized in the third band stacking register.

HM-151

•When a fourth frequency and operating mode are se- lected on a band, the first register set in step q, is over written.

28

Page 37
Image 37
Icom IC-7000 instruction manual Selecting an operating band, Using the band stacking registers, Band Register