FUNCTIONS FOR TRANSMIT

6

DCompression level setting

•Pre-setting the transceiver

[AF]

[MENU/GRP] [F-1] [F-2] [F-3]

[DIAL]

q Select an SSB mode.

w Turn the speech compressor function OFF, if it’s ON.

Select M-1.

•Push and hold [MENU/GRP] for 1 sec. once or

twice to select the menu group M.

•Push [MENU/GRP] momentarily one or more times to select the menu M-1.

Push [F-2COM] momentarily to turn the speech compressor function OFF.

•“ ” disappears.

e Select ALC meter.

Select S-1.

Push [F-3MET] one or more times to select the

ALC meter.

•“ALC” appears.

r Adjust the MIC gain.

Push [AF(SET)] momentarily to enter the set mode menu.

Push [F-1QS] to enter the quick set mode.

Push [F-1Y] or [F-2Z] to select “MIC Gain.”

Push [PTT] (microphone) to transmit at your normal voice level.

While speaking into the microphone, rotate [DIAL] so that the ALC meter reads within the ALC zone, whether you speak softly or loudly.

Push [Z(MENU/GRP)] twice to return normal op- erating mode.

•Compression level setting

[MENU/GRP] [F-2] [F-3]

[DIAL]

q Select COMP meter.

Select S-1.

•Push and hold [MENU/GRP] for 1 sec. once or

twice to select the menu group S.

•Push [MENU/GRP] momentarily one or more times to select the menu S-1.

Push [F-3MET] one or more times to select the COMP meter.

•“ ” appears.

w Turn ON the speech compressor function and enter the speech compression level set mode.

Select M-1.

Push [F-2COM] for 1 sec. to enter the speech

compression level set mode.

•speech compressor function automatically turns ON.

e Rotate [DIAL] so that the COMP meter reads be- tween 10 dB to 20 dB.

Appears

NOTE: When the ALC meter peaks below the ALC zone, your transmitted voice may be distorted.

ALC

ALC zone

Adjust ‘COMP LEVEL’ so that the ALC meter peaks above the ALC zone.

6

COMP Level

This item adjusts the speech compression level. The speech compression level can be adjusted from 0 to 10.

• Push [F-4DEF] for 1 sec. to return to default level.

5

5 (default)

90

Page 99
Image 99
Icom IC-7000 instruction manual Compression level setting, Comp Level, Select Comp meter Select S-1