5FUNCTIONS FOR RECEIVE

DCenter mode

Displays signals around the displayed frequency within the selected span. The set frequency is always displayed at the center of the screen.

q Set a mode and frequency. w Select G-1(Scope).

•Push and hold [MENU/GRP] for 1 sec. once or twice

to select the menu group G (Graphic).

•Push [MENU/GRP] momentarily one or more times to select the menu G-1(Scope).

[F-1]

 

 

[MENU/GRP]

[F-2]

[F-3]

[F-4]

e Push [F-3FIX] momentarily to select the center mode.

•“= ” appears when the center mode is selected.

r Push [F-4SPD] momentarily to select the sweep speed.

•“” or “≈≈” appears when Slow speed or Fast speed is selected, respectively.

t Push [F-1SPN] one or more times to select the desired steps.

•±10, 25, 50, 100 and 250 kHz are available.

•Push and hold [F-1SPN] for 1 sec. to select the ±10 kHz step.

•The simple band scope operates in the peak level hold mode. Peak levels are displayed in the background of the current spectrum in a different color until the receive frequency changes. This can be cleared by pushing and holding [F-2HLD] for 1 sec., or deactivated in the scope set mode. (below)

y Push [F-2HLD] to freeze the current spectrum dis- play and range.

•“H” and readout frequency indicator appear while the function is in use.

NOTE: If there is a lot of signal noise, turn the pre-

amp OFF and the attenuator ON (p. 74) to reduce

the input level and improve the readability of the scope.

DScope set mode

This set mode is used to set the peak hold function and scope size setting.

q Select G-1(Scope).

 

 

 

 

 

 

 

 

 

 

•Push and hold [MENU/GRP] for 1 sec. once or twice

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to select the menu group G (Graphic).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

•Push [MENU/GRP] momentarily one or more times to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

select the menu G-1(Scope).

 

 

 

 

 

 

 

 

 

 

[MENU/GRP] [F-1] [F-2] [F-4]

[DIAL]

 

 

w Push and hold [F-4SPD] for 1 sec. to enter the

 

 

scope set mode.

 

 

e Push [F-1] or [F-2] to select the desired set

 

 

item.

 

 

r Set the desired condition using [DIAL].

 

 

 

•Push [F-4DEF] for 1 sec. to select a default condition.

 

 

t Push [Z(MENU/GRP)] to exit from set mode.

 

 

73

Page 82
Image 82
Icom IC-7000 Center mode, Scope set mode, Push F-3FIX momentarily to select the center mode, Select G-1 Scope