16 OPTION UNITS SETTING

AT-180 internal switch description

The optional AT-180 has 3 operating conditions for HF band operation. Select a suitable condition according to your antenna system.

q Remove the top cover of the AT-180.

w Set the tuner switches to the desired positions ac- cording to the table below.

AT-180 inside top cover

SW

Position

Operation

AThe tuner operating condition is set by S2 (default) described below.

 

 

THROUGH INHIBIT

 

 

The tuner tunes the antenna even when the

S1

 

antenna has poor SWR (up to VSWR 3:1

 

after tuning). In this case, manual tuning is

 

 

 

B

necessary each time you change the fre-

 

quency although the tuner automatically

 

 

 

 

starts tuning when the VSWR is higher than

 

 

3:1. This setting is called “through inhibit,

 

 

however, the tuner is set to “through” if the

 

 

VSWR is higher than 3:1 after tuning.

 

 

 

 

 

TUNER SENSITIVE CONDITION

 

 

The tuner tunes each time you transmit (ex-

 

C

cept SSB mode). Therefore, the lowest

 

SWR is obtained at any given time.

 

 

S2

 

For SSB mode, the same condition as the

 

“D” position.

 

 

NORMAL CONDITION

DThe tuner tunes when the SWR is higher (default) than 1.5:1. Therefore, the tuner activates

only when tuning is necessary.

S2 S1

DCBA

Specifications for the AT-180

•Frequency coverage : 1.9–54 MHz

•Input impedance

: 50 Ÿ

•Maximum input

: 120 W

power

 

•Minimum tuning

: 8 W

power

 

•Matching impedance : 16.7–150 Ÿ (HF band)

range

20–125 Ÿ (50 MHz band)

•Tuning accuracy

: Less than SWR 1.5:1

•Insertion loss

: Less than 1.0 dB

 

(after tuning)

•Power supply

: 13.8 V DC/1 A (supplied from

requirements

the transceiver’s ACC socket)

•Dimensions (mm/in)

: 167(W) 58.6(H) 225(D)

 

6916(W) 2517(H) 878(D)

•Weight

: 2.4 kg; 5 lb 4 oz

•Supplied accessories : coaxial cable (1 m), ACC cable (DIN 13 pins)

Connector information for ACC(2) socket

4

2

5

1

 

3 ACC 2

6

 

7

PIN NO./

DESCRIPTION

NAME

 

q 8 V

Regulated 8 V output.

(10 mA max.)

 

 

 

w GND

Connects to ground.

 

 

 

Input/output pin.

e SEND

Goes to ground when transmitting (20 mA

 

max). When grounded, transmits.

 

 

r BAND

Band voltage output.

(Varies with amateur band; 0 to 8.0 V).

 

 

 

t ALC

ALC output voltage (–4 to 0 V).

 

 

y NC

No connection.

 

 

u 13.8V

13.8 V output when power is ON (1 A max).

 

 

143