13 SET MODE

Quick set mode (continued)

Side Tone Level (CW mode)

This item adjusts the CW side tone level from 0% to 100% in 1% steps.

See p. 43 for details.

50%

50% (default)

Side Tone Level Limit (CW mode)

This item allows you to set a maximum volume level for CW side tones. CW side tones are linked to the [AF] control until a specified volume level is reached

further rotation of the [AF] control will not increase the volume of the CW side tones.

ON

OFF

CW side tone level is limited

CW side tone level is linked

with [AF] (default)

to [AF]

Twin Peak Filter (RTTY mode)

This item turns the twin peak filter ON and OFF.

ON

OFF

 

Twin peak filter is ON

Twin peak filter is OFF. (de-

 

 

fault)

RTTY Mark Frequency (RTTY mode)

This item selects the RTTY mark frequency. RTTY mark frequency is switched between 1275, 1615 and 2125 Hz.

2125

1275

2125 Hz RTTY mark

1275 Hz RTTY mark

frequency (default)

frequency

RTTY Shift Width (RTTY mode)

This item adjusts the RTTY shift width. There are 3

170

425

selectable values: 170, 200 and 425 Hz.

170 Hz RTTY shift

425 Hz RTTY shift

 

 

frequency (default)

frequency

RTTY Keying Polarity (RTTY mode)

This item selects the RTTY keying polarity. Normal or reverse keying polarity can be selected.

When reverse polarity is selected, Mark and Space are reversed.

- Normal

: Key open/close = Mark/Space

- Reverse

: Key open/close = Space/Mark

NormalReverse

Normal polarity (default)

Reverse polarity

125

Page 134
Image 134
Icom IC-7000 instruction manual Side Tone Level CW mode, Side Tone Level Limit CW mode, Twin Peak Filter Rtty mode