Programming a Coverage VMS Off Button
This feature prevents unanswered external calls from receiving coverage by the MERLIN Messaging System. It
can be programmed at the user’s telephone or through Centralized Telephone Programming. The Centralized
Telephone Programming procedure is documented below.
To program a Coverage VMS Off button:
Step Programming Task Console Input/Selection PC Input/Selection
1Enter Programming mode
Sys Program
Exit/Start
[any key]
2Display next page of menu /
3Select Centralized
Telephone Programming Cntr-Prg
4Select Program Extension Program Ext
5Enter the extension you
want to program [nnn] Enter [nnn]
6Start Centralized Telephone
Programming Start
7Select line/feature button Press button on console or + function
key, then
8Select Coverage VMS Off
feature or
ListFeature
/
CoverageVMS
or
Function key corresponding to
CoverageVMS
9Return to System
Programming menu Sys Program
Exit/Back
Exit/Back