Chapter 7 Setting media bay module DIP switches 89

Table 12 Possible media bay module DIP switch settings for double density

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Media bay module

 

 

DIP switch settings

 

 

 

 

DIP switch settings

DS30

positioning

 

 

 

 

 

 

 

Offsets

 

 

 

 

 

 

 

 

 

 

bus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSM16+

DSM32+

1

2

3

4

5

6

ASM8/ASM8+

1

2

 

3

 

4

5

6

 

 

 

 

#

 

Offsets 0, 1

Offset 0

 

(offset)

(DS30)

 

 

Offsets 0, 1, 2, 3

(offset)

(DS30)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

 

off

on

on

on

on

on

0

0

on

 

on

on

on

on

on

02

 

 

 

 

off

on

off

on

on

on

1

1

on

 

on

 

off

 

on

on

on

 

1

 

 

 

 

 

 

 

 

 

2

2

on

 

off

 

on

on

on

on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

3

on

 

off

 

off

 

on

on

on

 

 

 

0

0

 

off

on

on

on

on

off

0

0

on

 

on

on

on

on

off

03

 

 

 

 

off

on

off

on

on

off

1

1

on

 

on

 

off

 

on

on

off

 

1

 

 

 

 

 

 

 

 

 

2

2

on

 

off

 

on

on

on

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

3

on

 

off

 

off

 

on

on

off

 

 

 

0

0

 

off

on

on

on

off

on

0

0

on

 

on

on

on

off

on

04

 

 

 

 

off

on

off

on

off

on

1

1

on

 

on

 

off

 

on

off

on

 

1

 

 

 

 

 

 

 

 

 

2

2

on

 

off

 

on

on

off

on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

3

on

 

off

 

off

 

on

off

on

 

 

 

0

0

 

off

on

on

on

off

off

0

0

on

 

on

on

on

off

off

05

 

 

 

 

off

on

off

on

off

off

1

1

on

 

on

 

off

 

on

off

off

 

1

 

 

 

 

 

 

 

 

 

2

2

on

 

off

 

on

on

off

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

3

on

 

off

 

off

 

on

off

off

 

 

 

0

0

 

off

on

on

off

on

on

0

0

on

 

on

on

 

off

on

on

06

 

 

 

 

off

on

off

off

on

on

1

1

on

 

on

 

off

 

off

on

on

 

1

 

 

 

 

 

 

 

 

 

2

2

on

 

off

 

on

 

off

on

on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

3

on

 

off

 

off

 

off

on

on

 

 

 

0

0

 

off

on

on

off

on

off

0

0

on

 

on

on

 

off

on

off

07***

 

 

 

 

off

on

off

off

on

off

1

1

on

 

on

 

off

 

off

on

off

 

1

 

 

 

 

 

 

 

 

 

2

2

on

 

off

 

on

 

off

on

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

3

on off

off off on off

 

Module set to offset 0

 

 

Module set to offset 1

 

 

Module set to offset 2

 

 

Module set to offset 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Each shaded square represents the amount of the DS30 bus, and the offset, which the module requires.

 

 

 

***If your system is configured with a 3/5 DS30 split, DS30 07 is not available to media bay modules.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation and Maintenance Guide