164Chapter 14 Troubleshooting

3To set the parameters for the System Status Sanity check, click the LED Settings tab. The LED Settings record appears.

Figure 72 System Status Monitor LED Settings record

Table 39 lists the values on the LED Settings screen.

Table 39 LED Display screen settings

Attribute

Values

Description

 

 

 

Version

Read only.

The current version of the LED monitoring application.

 

 

 

Reset

Yes, No, N/A

Use Yes to allow the system status monitor board to reset the

 

 

computing platform in the event that the sanity check fails the

 

 

user set parameters.

 

 

 

Sanity Time

60-255

The time in seconds between sanity checks.

 

Default: 240

 

 

 

 

Timeouts

0-254

The number of sanity checks that must fail before the system

 

Default: 10

status monitor sends a reset signal to the computing platform.

 

 

 

 

 

Emergency telephone does not function

If the emergency telephone is connected to the system, use the following procedure:

1Check the power LED on the ASM 8 to check that the ASM 8 is receiving power.

2Check that the emergency telephone has dial tone.

3Check the external line and emergency telephone connections.

4To avoid damage to the emergency telephone, connect the telephone directly to the external line and check for dial tone.

5Replace the MSC.