Page 161
Image 161

Chapter 10 Wiring the modules 135

Figure 56 shows the wiring pin-out for a BRI to the service provider (BRI loop set to T)

Warning: The BRI must only be connected to an NT1 provided by the service provider. The NT1 must provide a Telecommunication Network Voltage (TNV) to Safety Extra Low Voltage (SELV) barrier.

This diagram also applies to an S-Loop BRI, allowing connection to such S-Loop devices as video phones, terminal adapters, and Grp 3 Fax machines. Note: the S-loop does not supply supplementary power, such as required by video devices. Supplementary power must be supplied by a separate power supply.

Figure 56 BRI RJ45 wiring array

BRI connector

8 7 6 5 4 3 2 1

 

 

Pin #/connection

System side

 

 

1

not used

 

 

 

2

not used

 

 

 

 

 

 

3

+RX

+TX

RJ45 sockets

4

+TX

+RX

 

 

5

- TX

- RX

 

 

6

-RX

-TX

 

 

7

not used

 

 

 

8

not used

 

3Insert the connector into the jack on the module.

4You can now use the Unified Manager to configure the lines or sets associated with the module.

Refer to the Business Communications Manager Programming Operations Guide for steps about changing the default settings for each line/loop.

Installation and Maintenance Guide

Page 161
Image 161