136 Chapter 10 Wiring the modules

Wiring media bay modules to internal connections

After you have the trunk modules wired, you can install the wiring to the station modules. These are the modules which connect to the internal telephone sets.

All station module wiring uses 25-pair cable with a female amphenol connector at the media bay module end.

Note: DSM 32 modules require two 25-pair cables.

Follow these steps to connect the wiring for the DSM 16, DSM 32, ASM 8, ASM8+, or 4X16 modules:

1Wire 16 wire pairs from the amphenol connector to the local connecting blocks so they connect to the 16 station sets you want connected to this module.

Use Table 34 and Figure 57 on page 137.

Note: Use 16 wire pairs from each connector for the DSM 32.

Note: If you are connecting an DSM 16, 4X16, or DSM 32, use Table 34 on page 137. If you are connecting an ASM 8 or ASM8+, use the Table 35 on page 138.

For an overview of BIX wiring conventions, refer to the Business Communications Manager BIX Box Wiring Guide.

2Install the telephones and peripheral equipment wiring (if new system): a Attach the cables for the telephones to the connecting blocks.

b Install the telephones. Each telephone comes with hardware installation instructions. Refer also to Chapter 13, “Installing optional telephony equipment,” on page 157.

Note: You can configure most types of telephones before they are installed. Refer to the Programming Operations Guide for specific instructions about telephone settings and using the New Users Wizard to set up telephones.

cTo connect analog equipment to a digit line, refer to Chapter 12, “Installing Analog Terminal Adapters,” on page 149.

P0609324 01

Page 162
Image 162
Nortel Networks BCM1000 manual Wiring media bay modules to internal connections, Use and on