Nortel Networks BCM1000 manual Replacing the cooling fan, Installing piggy-backed fans

Models: BCM1000

1 311
Download 311 pages 52.93 Kb
Page 227
Image 227

Chapter 17 Adding or replacing a cooling fan 201

Replacing the cooling fan

To replace the fan in the BCM1000, follow these steps:

1Place the new fan in the BCM1000 in the position from which you removed the failed fan.

Note: Ensure the label of the new fan faces the back wall of the BCM1000.

Note: Piggy-backed redundant fan

If you are installing or replacing a piggy-back redundant fan in a version 2.0 BCM1000 that has been updated with a redundant power supply, place the redundant fan against the existing fan. Ensure that the blades are positioned in the same direction as the existing fan (fan labels both face in the same direction).

Use the four screws and nuts that are supplied with the redundant fan to attach the redundant fan to the existing fan.

Figure 108 Installing piggy-backed fans

2Align the screw holes in the fan with the screw holes on the BCM1000.

Note: Side-by-side redundant fan

If you are installing a second fan in a 2.5-model BCM1000, you must remove the cover label on the back of the server to expose the fan air holes and mounting holes.

3Attach the fan to the BCM1000 using the four screws

(2.0 hardware) or plastic rivets (2.5 hardware). Refer to Figure 107 on page 200.