Chapter 7 Setting media bay module DIP switches 95

CTM/GATM DIP switch settings

Table 17 shows the switch settings for each DS30 bus, and the resulting line assignments for CTMs/GATM4s and CTM8s/GATM8s.

Table 17 CTM/GATM4 and CTM8/GATM8 DS30 and offset switch settings

Select

Select

Enter these switch settings

To assign

 

DS30

offset

 

 

 

 

 

 

these lines

 

bus #

 

 

 

 

 

 

 

CTM/GATM4

 

 

1

2

3

4

5

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

on

on

on

on

on

on

211-214

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

on

on

 

on

on

on

219-222

 

 

 

 

 

 

 

 

 

02

 

 

off

 

 

 

 

 

 

 

 

 

 

 

 

2

on

 

on

on

on

on

227-230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

on

 

 

on

on

on

235-238

 

 

 

 

 

 

 

 

 

 

 

off

off

 

 

 

 

 

 

 

 

 

 

 

 

 

0

on

on

on

on

on

 

181-184

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off

 

 

 

 

 

 

 

 

 

 

 

1

on

on

 

on

on

 

189-192

 

 

 

 

 

 

 

 

 

03

 

 

off

 

 

off

 

 

 

 

 

 

 

 

2

on

 

on

on

on

 

197-200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off

 

 

 

off

 

 

 

 

 

 

 

 

 

 

3

on

 

 

on

on

 

205-208

 

 

 

 

 

 

 

 

 

 

 

off

off

 

 

off

 

 

 

 

 

 

 

 

 

0

on

on

on

on

 

on

151-154

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off

 

 

 

 

 

 

 

 

 

 

 

 

1

on

on

 

on

 

on

159-162

 

 

 

 

 

 

 

 

 

04

 

 

off

 

off

 

 

 

 

 

 

 

 

 

2

on

 

on

on

 

on

167-170

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off

 

 

off

 

 

 

 

 

 

 

 

 

 

 

3

on

 

 

on

 

on

175-178

 

 

 

 

 

 

 

 

 

 

 

off

off

 

off

 

 

 

 

 

 

 

 

 

 

0

on

on

on

on

 

 

121-124

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off

off

 

 

 

 

 

 

 

 

 

 

1

on

on

 

on

 

 

129-132

 

 

 

 

 

 

 

 

 

05

 

 

off

 

off

off

 

 

 

 

 

 

 

2

on

 

on

on

 

 

137-140

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off

 

 

off

off

 

 

 

 

 

 

 

 

 

3

on

 

 

on

 

 

145-148

 

 

 

 

 

 

 

 

 

 

 

off

off

 

off

off

 

 

 

 

 

 

 

 

0

on

on

on

 

on

on

91-94

 

 

 

 

 

 

 

 

 

 

 

 

 

off

 

 

 

 

 

 

 

 

 

 

 

 

 

1

on

on

 

 

on

on

99-102

 

 

 

 

 

 

 

 

 

06

 

 

off

off

 

 

 

 

 

 

 

 

 

 

2

on

 

on

 

on

on

107-110

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off

 

off

 

 

 

 

 

 

 

 

 

 

 

 

3

on

 

 

 

on

on

115-118

 

 

 

 

 

 

 

 

 

 

 

off

off

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To assign these lines.

CTM8/GATM8

Lower

Upper

(Lines 1-4)

(lines 5-8)

 

 

211-214

219-222

219-222

227-230

227-230

235-238

Not supported

Not supported

181-184

 

189-192

189-192

197-200

197-200

205-208

Not supported

Not supported

151-154

159-162

 

 

159-162

167-170

167-170

175-178

Not supported

Not supported

 

 

121-124

129-132

129-132

137-140

137-140

145-148

Not supported

Not supported

91-94

99-102

 

 

99-102

107-110

107-110

115-118

Not supported

Not supported

 

 

Installation and Maintenance Guide

Page 121
Image 121
Nortel Networks BCM1000 manual CTM/GATM DIP switch settings, CTM/GATM4 and CTM8/GATM8 DS30 and offset switch settings