Nortel Networks BCM1000 manual DSM wiring chart, Sets Pin Wire color Port 1st 2nd

Models: BCM1000

1 311
Download 311 pages 52.93 Kb
Page 163
Image 163

Chapter 10 Wiring the modules 137

Table 34 and Figure 57 provide the wiring scheme for the DSM 16, 4X16 and DSM 32 modules. The Sets heading indicates the position of the set on the BIX block. Set DNs are allocated by the Business Communications Manager based on the DS30 bus setting on the station module.

Figure 57 Wiring for DSM 16, 4X16, and DSM 32

 

 

25-pair connector

 

T=Tip

1 R

26 T

 

 

 

R=Ring

2R

 

 

 

27T

 

 

 

 

 

3R

28T

 

 

4R

DSM 16, 4X16

 

29T

 

5R

 

 

 

30T

 

 

6R

 

 

31T

 

 

7R

32T

 

 

8R

33T

 

 

9R

34T

 

 

10R

 

 

35T

 

 

11R

36T

 

 

12R

37T

 

 

13R

 

 

38T

 

 

14R 39T

15R 40T

16R 41T

DSM 32

The second 25-pair connector is wired in the same sequence as the first one

Table 34 DSM wiring chart

 

 

 

Sets

Sets

Pin

Wire color

Port

1st

2nd

 

 

 

 

 

26

White-Blue

X01

1

17

1

Blue-White

X01

1

17

27

White-Orange

X02

2

18

2

Orange-White

X02

2

18

 

 

 

 

 

28

White-Green

X03

3

19

3

Green-White

X03

3

19

29

White-Brown

X04

4

20

4

Brown-White

X04

4

20

 

 

 

 

 

30

White-Slate

X05

5

21

5

Slate-White

X05

5

21

31

Red-Blue

X06

6

22

6

Blue-Red

X06

6

22

 

 

 

 

 

32

Red-Orange

X07

7

23

7

Orange-Red

X07

7

23

33

Red-Green

X08

8

24

8

Green-Red

X08

8

24

 

 

 

 

 

34

Red-Brown

X09

9

25

9

Brown-Red

X09

9

25

35

Red-Slate

X10

10

26

10

Slate-Red

X10

10

26

 

 

 

 

 

36

Black-Blue

X11

11

27

11

Blue-Black

X11

11

27

37

Black-Orange

X12

12

28

12

Orange-Black

X12

12

28

 

 

 

 

 

38

Black-Green

X13

13

29

13

Green-Black

X13

13

29

39

Black-Brown

X14

14

30

14

Brown-Black

X14

14

30

 

 

 

 

 

40

Black-Slate

X15

15

31

15

Slate-Black

X15

15

31

41

Yellow-Blue

X16

16

32

16

Blue-Yellow

X16

16

32

 

 

 

 

 

42-40

no connections

 

 

 

17-25

 

 

 

 

 

 

 

 

 

Installation and Maintenance Guide

Page 163
Image 163
Nortel Networks BCM1000 manual DSM wiring chart, Sets Pin Wire color Port 1st 2nd