Nortel Networks BCM1000 manual RAID board LEDs, RAID board LED states

Models: BCM1000

1 311
Download 311 pages 52.93 Kb
Page 221
Image 221

Chapter 16 Replacing the hard disk 195

RAID board LEDs

The front end of the board fits into the card slot that is closest to the media bay modules on the BCM1000. The front panel of the board contains a number of LEDs that indicate the status of the RAID board and the current connection with the hard drives. Refer to Figure 101 and Table 40.

Figure 101 RAID board LEDs

Status

Mirrored hard disk

Primary hard disk

Note: The BCM1000 does not use the Slave channel on the RAID board, therefore, the Slave Status LED will always remain solid red.

Table 40 RAID board LED states

LED state

Primary and Mirror LEDs

Status LEDs

 

 

 

Solid Green

Drive installed on the current channel.

Drives are in mirror mode, data is identical.

 

 

 

Flashing Green

N/A

Drives may not be identical.

 

 

 

Solid Red

Drive not installed.

Drives are not in mirror mode.

 

 

 

Flashing Red

The channel is marked as bad.

Copy/Compare in progress.

 

 

 

Solid Orange

Channel activity (read/write).

Copy/Compare in progress (under windows).

 

 

 

Flashing Orange

Scanning the channel for drives.

N/A

 

 

 

Installation and Maintenance Guide

Page 221
Image 221
Nortel Networks BCM1000 manual RAID board LEDs, RAID board LED states, LED state Primary and Mirror LEDs Status LEDs