194Chapter 16 Replacing the hard disk

Power routing for 2.0 hardware

Follow these steps to connect power to the hard disks, the media bay module housing, and to the RAID board. Refer to Figure 100. Each step number in the following procedure corresponds to an item in the diagram.

1Select two power cables that have three Molex female connectors and route them under the power supply and media services card (MSC), along the bottom of the chassis.

2Connect the end connector of the first cable to the secondary hard disk (top disk).

3Connect the next connector of the first cable to the Primary hard disk (bottom disk).

4Connect the last connector of the first cable to the RAID card.

5Connect the end connector of the second cable to the bottom of the media bay module back plane

Do not attempt to connect any other component to the second and third connectors on this cable.

Figure 100 Connecting the power cables for mirrored disks, 2.0 version of BCM1000

 

 

4

 

5

 

 

2

Leave

 

unconnected

 

 

 

3

 

 

 

1

P0609324

01

 

Page 220
Image 220
Nortel Networks BCM1000 manual Power routing for 2.0 hardware