104Chapter 7 Setting media bay module DIP switches

Companion has not be included in this table because you cannot use double density modules to deploy Companion.

Table 25 DSM 16+ and DSM32+ double density switch settings for new systems with BCM 3.0 or newer software

Select DS30

bus #

02

03

04

05

06

071

 

Enter these switch

 

 

 

 

 

settings

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

 

6

 

 

 

 

 

 

 

 

 

A

 

 

on

on

on

on

 

on

 

 

 

 

 

 

 

 

 

off

 

 

 

 

 

 

 

 

 

 

on

 

on

on

on

B

 

 

 

 

 

 

 

 

 

off

 

 

off

 

 

 

 

 

 

 

on

on

on

on

 

A

 

 

 

 

 

 

 

 

 

off

 

 

 

 

 

 

off

 

 

 

on

 

on

on

 

 

B

 

 

 

 

 

 

 

 

 

off

 

 

off

 

 

 

off

 

 

 

on

on

on

 

 

on

A

 

 

 

 

 

 

 

 

 

off

 

 

 

 

off

 

 

 

 

on

 

on

 

 

on

B

 

 

 

 

 

 

 

 

 

off

 

 

off

 

off

 

 

 

 

on

on

on

 

 

 

A

 

 

 

 

 

 

 

 

 

off

 

 

 

 

off

off

 

 

 

on

 

on

 

 

 

B

 

 

 

 

 

 

 

 

 

off

 

 

off

 

off

off

 

 

 

on

on

 

on

on

A

 

 

 

 

 

 

 

 

 

off

 

 

 

off

 

 

 

 

 

 

on

 

 

on

on

B

 

 

 

 

 

 

 

 

 

off

 

 

off

off

 

 

 

 

 

 

on

on

 

on

 

A

 

 

 

 

 

 

 

 

 

off

 

 

 

off

 

 

off

 

 

 

on

 

 

on

 

 

B

 

 

 

 

 

 

 

 

 

off

 

 

off

off

 

 

off

 

 

 

 

 

 

 

 

 

 

To assign these

DNs

to DSM 16+:

A= DSM1, B=DSM2

221-236

237-252

253-268

269-284

285-300

301-316

317-332

333-348

349-364

365-3803

381-396

397-4124

A

B

A

B

A

B

A

B

A

B

A

B

To assign these DNs to

2

Custom DN

DSM 32+ (connectors:

 

range

A=top, B = bottom)

 

 

 

 

 

 

237-252

221-236

269-284

253-268

301-316

285-300

333-348

317-332

365-3803

349-364

397-4124

381-396

2The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a different Start DN, enter the range in the blank column.

1If your system is configured with a 3/5 split, you cannot use DS30 07.

3Available only on systems set to FDD. Modules cannot be set to double density on systems set to PDD. Refer to the previous chart for the switch settings for single density and PDD.

4Available only on systems set to FDD, with a 2/6 DS30 split. Modules cannot be set to double density on systems set to PDD. Refer to the previous chart for the switch settings for single density and PDD.

P0609324 01

Page 130