108Chapter 8 Installing media bay modules

Shutting down the system

Before you perform any maintenance procedures, read the following warnings to ensure you and your system are properly protected.

Warning: If you are installing a new system, or new BCM1000 or BCM1000e, refer to Chapter 11, “Installing telephones and peripherals,” on page 141 for instructions about installing a new system before you connect the system to the ac power outlet.

Warning: DO NOT continue with module installation until you ensure the BCM1000 and BCM1000e are set to the correct voltages (version 2.0 systems with standard power supply).

Warning: Failure to follow procedures to properly disconnect the BCM1000 and BCM1000e, can result in module or system damage.

Warning: Ensure you are properly grounded before handling modules or any components that are part of the Business Communications Manager hardware.

This section describes the recommended procedure for shutting down the Business Communications Manager system prior to installing new modules.

1If you are adding or replacing a module in an active system, follow these steps first: a Choose System.

b Click the Logoff menu and then click Shutdown. c Click the Yes button.

d Wait until the Status changes to Complete! It is safe to turn off the system. e Click the Done button.

f Exit the Unified Manager.

2Attach one end of the grounding strap to your wrist and the other end to a grounded metal surface.

3Ensure the cables connected to the front of the base unit and the expansion unit are clearly marked.

4Remove the cables from all the media bay modules and the MSC on the BCM1000 front panel and the BCM1000e, if there is one.

5Disconnect the BCM1000 and BCM1000e power cords from the ac outlet.

P0609324 01

Page 134
Image 134
Nortel Networks BCM1000 manual Shutting down the system, Installing media bay modules