Chapter 7 Setting media bay module DIP switches 103

Companion has not be included in this table because you cannot use modules set to double density to deploy Companion.

Table 24 DSM 16+ and DSM32+ double density switch settings for 2.5 systems upgraded to BCM 3.0 or newer software

Select

 

Enter these switch

 

 

 

 

settings

 

 

 

DS30

 

 

 

 

 

 

 

 

 

 

 

 

bus #

1

2

3

4

5

6

 

 

 

 

 

 

 

 

A

 

 

on

on

on

on

on

02

 

 

 

 

 

 

 

off

 

 

 

 

 

 

 

 

on

 

on

on

on

B

 

 

 

 

 

 

 

 

 

off

 

off

 

 

 

 

 

 

on

on

on

on

 

A

03

 

 

 

 

 

 

 

off

 

 

 

 

off

 

 

 

on

 

on

on

 

B

 

 

 

 

 

 

 

 

 

off

 

off

 

 

off

 

 

 

on

on

on

 

on

A

04

 

 

 

 

 

 

 

off

 

 

 

off

 

 

 

 

on

 

on

 

on

B

 

 

 

 

 

 

 

 

 

off

 

off

 

off

 

 

 

 

on

on

on

 

 

A

05

 

 

 

 

 

 

 

off

 

 

 

off

off

 

 

 

on

 

on

 

 

B

 

 

 

 

 

 

 

 

 

off

 

off

 

off

off

 

 

 

on

on

 

on

on

A

06

 

 

 

 

 

 

 

off

 

 

off

 

 

 

 

 

on

 

 

on

on

B

 

 

 

 

 

 

 

 

 

off

 

off

off

 

 

 

 

 

on

on

 

on

 

A

071

 

 

 

 

 

 

 

off

 

 

off

 

off

 

 

 

on

 

 

on

 

B

 

 

 

 

 

 

 

 

 

off

 

off

off

 

off

 

 

 

 

 

 

 

 

 

2To assign these DNs to DSM 16+:

(A=DSM1, B=DSM2)

221-236

377-392

237-252

393-408

253-268

409-424

269-284

425-440

285-300

441-4563

301-316

457-4724

A

B

A

B

A

B

A

B

A

B

A

B

To assign these DNs

 

to DSM 32+

2 Custom DN

(connectors:

range

A=top, B=bottom)

 

 

 

377-392

221-236

393-408

237-252

409-424

253-268

425-440

269-284

441-4563

285-300

457-4724

301-3164

1If your system is configured with a 3/5 split, you cannot use DS30 07 for the DSM 16 module.

2The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a different Start DN, enter the range in the blank column.

3Available only on systems set to FDD. Modules cannot be set to double density on systems set to PDD. Refer to the previous chart for the switch settings for single density and PDD.

4Available only on systems set to FDD, with a 2/6 DS30 split. Modules cannot be set to double density on systems set to PDD. Refer to the previous chart for the switch settings for single density and PDD.

Installation and Maintenance Guide

Page 129
Image 129
Nortel Networks BCM1000 manual To assign these DNs to DSM 16+ =DSM1, B=DSM2, To DSM 32+ Custom DN Connectors Range