132 Chapter 10 Wiring the modules

Figure 52 Process map: Trunk and station wiring process map

Trunk and station modules

Media bay modules installed.

Read warnings

Wire cables to telco demarcation block

Connect cables to appropriate trunk modules.

Wire internal 25-pair cables to station set distribution BIX block for your building

Connect amphenol cable to appropriate station modules

Continue with setup procedures

Module wiring warnings

Warning: Electrical shock warning.

The Business Communications Manager media bay modules have been Safety approved for installation into BCM1000 and BCM1000e. It is the responsibility of the installer and user to ensure that installation of the Business Communications Manager hardware does not compromise existing Safety approvals.

BEFORE YOU OPEN the BCM1000 or BCM1000e ensure that the cables are unplugged from the front of the unit, and the unit is disconnected from the ac power source.

Station modules: The ports on these modules are meant to be connected only to approved digital telephones and peripherals with the proper cables on a protected internal system.

Do not connect any telephones to wiring that runs outside of the building.

Read and follow the installation instructions carefully.

P0609324 01

Page 158
Image 158
Nortel Networks BCM1000 manual Module wiring warnings, Wiring the modules, Trunk and station modules