208 Chapter 18 Replacing a power supply

8Monitor the power LED. Refer to Table 43.

Table 43 Power supply LED

LED

 

Green

Green

 

Green

Label

Description

LED On

LED Flash

Red LED On (Only)

LED Off

 

 

 

 

 

 

 

 

 

Indicates state of system power.

OK

N/A

at least one power supply

N/A

 

 

 

 

 

requires attention*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Older models may not have a

 

 

 

 

 

 

Red LED

 

 

 

 

 

 

 

 

The Business Communications Manager system starts up when you connect the ac power cord. This takes several minutes to complete.

Upgrading to a redundant power supply

The redundant power supply allows you to change a failed power supply without turning off the system. You can add a redundant power supply to a BCM1000 currently equipped with a standard power supply.

Figure 115 provides an overview of the steps required to upgrade your system from a standard power supply to a redundant power supply module.

Figure 115 Process Map: Upgrading to a redundant power supply

 

 

 

 

 

 

 

 

 

 

 

 

 

Shut the system

 

 

Make internal

 

 

Turn power

 

 

down

 

 

connections

 

 

module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

switches on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ensure power

 

 

 

 

 

 

Set up unit for

 

 

 

 

 

 

 

 

 

 

module switches

 

 

 

 

 

 

maintenance

 

 

 

 

Restore unit to

 

 

 

 

are off

 

 

 

 

 

 

 

 

 

 

operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove

 

 

Insert both

 

 

 

 

 

 

standard power

 

 

 

 

Check power LED

 

 

 

 

modules into

 

 

 

 

supply

 

 

power supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

housing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install redundant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

housing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P0609324 01