Chapter 13 Installing optional telephony equipment 159

2Connect the paging system relay to the Page relay output on the MSC. Refer to Figure 67.

Figure 67 Page relay jack

Page relay jack

MSC faceplate

 

 

Ring

 

 

Tip

 

 

Sleeve

Tip:

Page relay output

Page relay

Ring:

Page relay output

 

Sleeve: Ground

 

Warning: The paging connections must not be connected to exposed plant.

Tip: Paging tips

Business Communications Manager external paging does not support talk back paging equipment unless you use an external line port.

The Business Communications Manager system provides paging over the telephone speakers when there is no external paging equipment.

External music source

(customer supplied)

You can use any approved low-power device as a music source. This would include equipment such as a radio with a high impedance earphone jack, as a music source.

Music on hold specifications

Ensure that the music source follows these guidelines.

Nominal input impedance is 3.3 kilohms.

Nominal sensitivity of this interface returned to digital encoded PCM is -22 dBm0 for a 0.25 V rms input signal.

The input is limited so that the encoded analog content at the digital interface to the network does not exceed -12 dBm when averaged over any three-second interval.

The maximum non-clipped input level is 1 V rms.

The interface is protected against ringing cross.