Responding to System Events

STATUS

Message

Horn

Phone

Relay

Log*

Indication

Battery Switchgear Closed

No

No

No

H

User Status

 

 

 

 

 

 

Battery Switchgear Open

No

No

No

H

User Status

 

 

 

 

 

 

Bypass Switchgear Closed

No

No

No

H

User Status

 

 

 

 

 

 

Bypass Switchgear Open

No

No

No

H

User Status

 

 

 

 

 

 

Charger Status Off

No

No

No

H

User Status

 

 

 

 

 

 

Charger Status On

No

No

No

H

User Status

 

 

 

 

 

 

Check Heatsink Temp Sensor

No

No

No

No

Service Status

 

 

 

 

 

 

Check Heatsink Temp Sensor OK

No

No

No

No

User Status

 

 

 

 

 

 

Control Power Status Off

No

No

No

No

User Status

 

 

 

 

 

 

Control Power Status On

No

No

No

No

User Status

 

 

 

 

 

 

Heatsink Overtemperature

No

No

No

No

Service Status

 

 

 

 

 

 

Heatsink Overtemperature OK

No

No

No

No

User Status

 

 

 

 

 

 

Incoming Modem Call Started

No

No

No

H

User Status

 

 

 

 

 

 

Inverter Status Off

No

No

No

No

User Status

 

 

 

 

 

 

Inverter Status On

No

No

No

No

User Status

 

 

 

 

 

 

Modem Call Completed Successfully

No

No

No

H

User Status

 

 

 

 

 

 

Modem Connection Established

No

No

No

H

User Status

 

 

 

 

 

 

Outgoing Modem Call Started

No

No

No

H

User Status

 

 

 

 

 

 

Output Switchgear Open

No

No

No

H

User Status

 

 

 

 

 

 

Output Switchgear Open OK

No

No

No

H

User Status

 

 

 

 

 

 

Rectifier Phase L1 Current Limit

No

No

No

H

Service Status

 

 

 

 

 

 

Rectifier Phase L2 Current Limit

No

No

No

H

Service Status

 

 

 

 

 

 

Rectifier Phase L3 Current Limit

No

No

No

H

Service Status

 

 

 

 

 

 

Rectifier Status Off

No

No

No

H

User Status

 

 

 

 

 

 

Rectifier Status On

No

No

No

H

User Status

 

 

 

 

 

 

Rectifier Switchgear Closed

No

No

No

No

User Status

 

 

 

 

 

 

Rectifier Switchgear Open

No

No

No

No

User Status

 

 

 

 

 

 

Rectifier Tripped

No

No

No

H

User Status

 

 

 

 

 

 

System Alarm Active

No

No

1

No

User Status

 

 

 

 

 

 

System Notice Active

No

No

No

No

User Status

 

 

 

 

 

 

UPS Normal

No

No

No

H

User Status

*Log codes indicate where the UPS records the event: H = History log; HA = History and Active logs; and A = Active log only.