Vtrak
 Copyright
Trademarks
Important data protection information
Recommendations
 Contents
 VTrak Setup with the CLU
 Contents
 133
Management with the CLU
 Maintenance
 Technology Background
Support
 Introduction
About This Manual
 Overview
VTrak 15110 front view
 Architectural Description
Features and Benefits
Feature Benefit
 Allows you to manage the RAID subsystem
 Specifications
RAID
 FCC Statement
 Installation
Unpack the VTrak
 Mount VTrak 15110 in a Rack
Rackmounted VTrak
 Install Disk Drives
 VTrak 15110 Disk Drive access
 Drive Carrier mounting holes
 Serial ATA Disk Drives
Sata Disk Drives mount at the front of the carrier
 Parallel ATA Disk Drives
Pata Disk Drives require a PATA-to-SATA adapter
 Drive Numbering
VTrak disk drives are numbered left to right
 Verify the Scsi HBA Card
 Connect the Scsi Cables
VTrak 15110 Scsi connections
 Scsi Terminator
Pages
 Configuration 1 One VTrak, one Host PC, one Scsi HBA card
Configuration 2 One VTrak, one Host PC, two Scsi HBA cards
 Host PC
 Scsi
 Configuration 5 Two VTraks, one Host PC, two Scsi HBA cards
 RS-232 Serial Connection
Connect the Management Cables
Management Port Connection
 Connect the Power
Macintosh Users
 VTrak 15110 Displays
 Set-up Management Connections
Terminal Emulation
 Set IP Addresses and Subnet Mask
 Snmp
Page
 Set Up Telnet Connection
Enable Telnet on VTrak
Windows and Linux
Mac OS
 Make a Telnet Connection
HyperTerminal Windows or Minicom Linux
 Command Line Windows or Terminal Icon Linux
Page
 Install WebPAM PRO Software
Utility Server Installation Locations
Installation Guidelines
Operating System Support
 Cimom Agent
WebPAM PRO on a network
 Install WebPAM PRO
Internet Browser
Before you start…
Windows
 Solaris
 Installation Under All Supported Operating Systems
Page
 Installation
Page
 Installation
Page
 VTrak Setup with WebPAM PRO
Log-in to WebPAM PRO
Regular Connection
Http//192.168.10.468080/promise
 Secure Connection
Https//192.168.10.468443/promise
 Setup
 Access a Subsystem VTrak
Add a Subsystem VTrak
 Setup
 Create a Disk Array
 Automatic Option
Express Option
Page
 Advanced Option
Page
 Setup
 Create a Logical Drive
 Assign a Scsi Target ID
 Internet Connection using WebPAM PRO
Log-out of WebPAM PRO
 VTrak Setup with the CLU
CLU Connection
 Create a Disk Array Automatically
 Create a Disk Array Manually
 Maxtor 5A250J0
 RAID SBS CAP
 Mapping for Disk Array
 TIDs for Scsi channel 1 changed Press Enter key to return
 Exit the CLU
 VTrak Status Indicators
Management with WebPAM PRO
 Drive Status Indicators
State LEDs
 Audible Alarm
LEDs State
 Https//192.168.1.468443/promise
Log-in/Log-out
Http//192.168.1.468080/promise
 Management with WebPAM PRO
 WebPAM PRO Opening Screen
 Subsystem Management
Subsystem User Rights
 Right Meaning
 Access a Subsystem VTrak
 Subsystem Management Window
View Event Log
 Management with WebPAM PRO
 Delete a Subsystem
 User Management
Add a User
 Event Notification
 Meaning
 Connection between Host PC and UltraTrak has
 Meaning
 45C or discharge above 60C
 Delete a User
Manage User Rights
 Right Meaning
 Change Password
 Setup Email Alert Notification
 Software Management
Web Server
 Port number for secure connections is
 Firmware Update
 Tftp Server
 Security
Restart Tomcat Service Windows
Refresh Time
 Events
 Management with WebPAM PRO
 Connection Status
User Rights
 Subsystem Health
VTrak Management
Lock Operations
 MP/PDM Settings
 LUN Settings
Scsi Management
 TID Settings
 Ethernet
Network Management
Statistics
 Service
Service Management
Settings
 Snmp
 Controllers
Telnet
Controller List
Controller
 Controller Parameters
 Enclosures
Enclosure List
 Enclosure
FRU VPD
 Battery
Buzzer
 Physical Drive List
Enclosure Front View
 Physical Drive
Physical Drive Information
 109
 Disk Array Parameters
Disk Arrays
Disk Array List
 111
 112
 113
 Advanced Option
 115
 Delete Disk Array
 Disk Array Information
Disk Array Information
 Disk Array and Logical Drive Status Definitions
 Disk Array Settings
 Create Logical Drive
 Delete Logical Drive
Background Activity
 Scheduler
 Logical Drive List
Logical Drive Parameters
 Logical Drive
 Logical Drive Information
 Logical Drive LUN Settings
 Physical Drives
Spare Drives
Logical Drive Alias
 Spare Drive List
Create a Spare Drive
 Delete a Spare Drive
 Logical Drive Summary
 131
 132
 Management with the CLU
 134
 Management with the CLU
 Audible Alarm
Alarm Settings
 CLU Connection
Serial Connection
Telnet Connection
Telnet 192.168.1.56
 There are nine functional groups in the CLU
 139
 How to use the CLU
Please enter your menu choice4
 141
 CLU Function Map
 143
 144
 LUN
 146
 147
 Modify Controller Parameters
Controller Management
View Controller Information
 Reboot
VPD
 150
 Enclosure Management
Fan Speed
 Temperature
Voltage
 153
 Physical Drive Management
 Enable/Disable Write Cache
View Parameters
 Wipe Out Boot Sector
Wipe Out Reserve Sector
 Diagnostics
Blink LED
 Physical Drives IO Statistics
 WDC WD1200JD
 Disk Array Management
 Disk Array Auto Creation
 Create New Disk Array
 WDC WD2000JB-00FUA0
 Disk Array Properties
 Create Logical Drive
 Delete Logical Drive
Cache Policy
 Enable/Disable Smart
Retry Count
Disk Array Name
Priority
 Hot Spare Policy
PDM
 PDM Auto Start
Auto Rebuilding
 PDM Auto Start Disabled Enable PDM Auto starty/n?y
 171
 Scsi Assignment
Logical Drive Management
Name
 Management Port
 Enable/Disable Telnet
 Change User Name
Timeout
Change Password
 Reset to Default Settings
 Read only Community
Location
Contact Person
 Trap Sinks
Ping
Trap Only Community
 Number of ping packets1-30?5
 Channel TID
 RAID Console LUN
 Maintenance Menu Disk Array Operations
Rbld
 Maintenance Activity Monitor
Migrate Disk Array
 Manual Rebuild
Migrate Disk Array 1 nowy/n?y
 Manual PDM
RAID3
 Synchronize Logical Drive
Redundancy Check
 Media Patrol
 Event Viewer
 Maintenance
 Firmware Update WebPAM
Preparation
Tftp Server IP Address
Tftp Server Directory Name
 Firmware Image File
 Firmware Update CLU
Tftp Server
 193
 Firmware Update Serial Port
Firmware Image File
 Scrub DDR, waiting Platform Init Done
 Replace Power Supply
 Replace Cooling Unit Fan
 Disconnect
 199
 200
 201
 Replace Cache Battery
 Detach
 Replace SEP
 Replace RAID Controller
 206
 Technology Background
Introduction to RAID
 RAID 0 Striping
RAID 0 Striping interleaves data across multiple drives
 RAID 1 Mirroring
RAID 1 Mirrors identical data to two drives
 RAID 3 Block Striping with Dedicated Parity
RAID 3 Stripes data and adds a dedicated Parity Drive
 RAID 5 Block Striping with Distributed Parity
RAID 5 Stripes all drives with data and parity information
 RAID 10 Mirroring / Striping
 RAID 50 Striping of Distributed Parity
RAID 50 Striping of Distributed Parity disk arrays
 Choosing a RAID Level
Advantages Disadvantages
 215
 216
 Initialization
Choosing Stripe Block Size
Gigabyte Boundary
 Hot Spare Drives
Partition and Format the Logical Drive
 RAID Level Migration
Cache Settings
Where to Make Settings
 Performance
From Increase Redundancy Capacity
Add Lose
 Ranges of Disk Array Expansion
 Current LD Size Maximum LD Sector Size Expansion Size
 CLU Reports a Problem
VTrak is Beeping
 WebPAM PRO Reports a Problem
 Troubleshooting
 LEDs Display Amber or Red
Front Panel
 Connection
 Green
Drive Status Indicators
Dark Steady Flashing Amber Red
 Back of Enclosure
Dark Green Amber Red
 Event Notification Response
Event Action
Controller Notification
Connection Notification
 Logical Drive Notification,
Disk Notification
Logical Drive Notification
 232
 Enclosure Notification
 Rebuild
When a Disk Drive Fails
Critical & Offline Disk Arrays
 Without a Hot Spare Drive
Enclosure Problems
With a Hot Spare Drive
 236
 Overheating
 Power Supplies
Battery
 Serial Connections
Connection Problems
Scsi Connections
 Network Connections
 Frequently Asked Questions
What kind of disk drives can I use with VTrak?
Can I use my existing Scsi card with VTrak?
How many VTrak subsystems can I connect to one Scsi chain?
 How can I tell when the VTrak has fully booted?
Can WebPAM PRO connect through VTrak’s Serial RS-232 port?
 Are disk arrays on VTrak limited to 2.199 terabytes?
 How can I be sure everything is working OK on the VTrak?
 North & South America
Technical Support Services
Contacting Technical Support
 Europe, Africa, Middle East
Pacific Rim
 China
 Limited Warranty
Disclaimer of other warranties
 Returning Product For Repair
Your Responsibilities
 Or retailer
 Appendix a Serial Connector Pinout
Pin Signal
 252
 Index
 FRU LED 24, 65, 133
 RAID 0 208 RAID 1 209
 241