VTrak 15110 User Manual

11

ST380013AS

80 GB

12

WDC WD1200JD-00FYB0

120 GB

Enter Physical Drive ID to select.

Press R to continue after you have finished selecting Physical Drive.

Your input?>r

8.Press R to finish your selection and press Enter.

The Disk Array Properties submenu displays. Note that Hot Spare Policy has changed to Dedicated with the physical drive 9 (PD9) as the hot spare.

Stripe Block Size:

64K

 

 

Disk Array #1 Mapping: GB

 

 

-----------------------------------

 

 

100 GB 100 GB 39 GB

 

 

-----------------------------------

 

 

--------------------------------------------------------------------------

Name: Daniels Array

 

 

RAID Level:

5

Member LDs:

1-2

Stripe Block Size:

64K

Capacity:

240 GB

Member PDs:

1,3-4,7

SMART Check:

On

Cache Policy:

Write Through

Retry Count:

2

Auto Rebuilding:

On

Hot Spare Policy:

Dedicated(PD9)

Priority: High(RBLD), High(SYNC), High(Migration), High(RC), High(PDM)

--------------------------------------------------------------------------

Disk Array 1 Properties

1.Create Logical Drive

2.Delete Logical Drive

3.Cache Policy

4.Retry Count

5.Enable/Disable SMART

6.Name

7.Priority

8.Hot Spare

9.Auto Rebuilding

R. Return to Previous Menu

Please enter your menu choice>

This concludes the example.

CLU Function Map

The map below is designed to help you navigate to the submenu where each function is located. The paths in this map do not activate the functions.