VTrak 15110 User Manual
230
To check a component’s installation, follow the same procedure as replacing the
component, except that you reinstall the original component rather than a new
one. In most cases, this action fixes a bad connection and allows VTrak to detect
the component. If this action does not correct the problem, replace the unit. See
page189 for instructions.
Event Notification Response
When you select Event Notification, WebPAM PRO sends popup and/or email
messages regarding its status. The messages you see depend on your
notification selection (see page78) and what is currently happening in the VTrak.
The chart below gives the suggested action when the corresponding message is
displayed.
Event Action
Controller Notification
Controller Unknown Error Unspecified problem with the Controller.*
Data Parity Error SCSI data parity error.*
Command Parity Error SCSI command parity error.*
Bus Reset The Initiator sent a command to reset the SCSI bus,
to correct a problem.*
Unrecoverable Error Restart the Promise Product to clear the problem.*
Abort Task A normal event. Result of user action.
Clear ACA Cleared an auto contingent alliance condition.*
LUN Reset A normal event. Result of user action.
Initiator Error SCSI/FC initiator error.*
Illegal Secondary Identify A target received a second Identify message with a
different LUN.*
Message Parity Error SCSI/FC message parity error.*
Bus Reboot The VTrak rebooted itself.*
* An occasional incident of one of these messages
does not necessarily indicate a problem. However,
if any of these messages appears repeatedly,
contact Technical Support.
Connection Notification
Connection Made Normal result of logging in.
Connection
Notification, cont.